Data Logging

Pulse Input Adapters

Preview: 
Name: 
Pulse Input Adapters
Model: 
S-UCA/B-M006
Description: 

The Pulse Input Adapters are used to log the number of switch closures per interval and are designed to work with the HOBO Weather Station and Micro Station data loggers. The adapter has a plug-in modular connectore that allows it to be added easily to the Weather Station or Micro Station. Two versions are available for easy interfacing with either mechanical contact closures or solid-state electronic switches. The contact closure version is ideal for connecting to tipping bucket rain gauges.

Categories: 

Veris Industries Hawkeye Current Switch

Preview: 
Name: 
Hawkeye H600 Current Switch
Model: 
H600
Measures: 
Current/Amperage
Description: 

The H600 is a current-sensitive switching device which monitors current (amperage) in the conductor passing through it. A change in amperage in the monitored conductor which crosses the switch threshold will cause the resistance of the status output to change state, similar to the action of a mechanical switch. In this model, the threshold is fixed at 150mA AC max (200mA AC for 50Hz operation). The status output is suitable for connection to building controllers, or other appropriate data acquisition equipment operating at up to 30 volts. The H600 requires no external power supply to generate its output.
Go/No switch used with state logger-dent

Compatible Data Loggers: 

Go/No switch used with state logger-dent

Categories: 

HOBO U12-012 Data Logger

Preview: 
Name: 
HOBO U12 Data Logger
Model: 
U12-012
Measures: 
Temperature, Relative Humidity, Light and an External Channel
Resolution: 
12-bit
Memory: 
43,000 measurements
Description: 

The HOBO U12 Logger can record Temperature, Relative Humidity, and Light with 12-bit resolution and can record up to 43,000 measurements or events. The external channel accepts a variety of sensors, including temperature, and split-core AC current sensors as well as 4-20 mA

Sensor: Range (Accuracy): 

Temperature: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F),
RH: ±2.5% from 10% to 90% RH (typical), to a maximum of ±3.5%, see Plot B
Designed for indoor measurement of relative light levels
External input channel (see sensor manual): ± 2 mV ± 2.5% of absolute reading

Compatible Data Loggers: 

4-20mA, AC Current, AC Voltage, Air Velocity, Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Gauge Pressure, Kilowatts (kW), Temperature, Volatile Organic Compound

Categories: 