Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage.
The current and voltage measurements are used by the meter to to calculate power and energy (kW and kWh).
Standard Accuracy
Accuracy: ±0.75% from 1% to 120% of rated primary current
Phase angle: ±0.50 degrees (30 minutes) from 1% to 120% of rated current
IEEE C57.13 accuracy: class 1.2 from 1% to 120% of rated current
IEC 60044-1 accuracy: class 1.0 from 1% to 120% of rated current
Note: The ACT-0750-005 specifications apply at 120% of rated current only at temperatures of 40°C and below.

Categories: 

Continental Control Systems, LLC ACT Split-Core CT

Preview: 
Model: 
ACT-0750-020
Description: 

Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage.
The current and voltage measurements are used by the meter to to calculate power and energy (kW and kWh).
Standard Accuracy
Accuracy: ±0.75% from 1% to 120% of rated primary current
Phase angle: ±0.50 degrees (30 minutes) from 1% to 120% of rated current
IEEE C57.13 accuracy: class 1.2 from 1% to 120% of rated current
IEC 60044-1 accuracy: class 1.0 from 1% to 120% of rated current
Note: The ACT-0750-250 specifications apply at 120% of rated current only at temperatures of 40°C and below.

Categories: 

Dent RoCoil Flexible CT

Preview: 
Name: 
Dent RoCoil Flexible CT
Model: 
CT-RMV-16-1000
Measures: 
AC Current
Description: 

Like its name implies, the RoCoil mV produces a millivolt output for use with DENT’s ELITEpro and DATApro Series dataloggers. Available in standard lengths up to 72” and current ranges up to 6000A. The RoCoil mV requires 5-24V dc, which can be supplied from the Line-Powered ELITEpro or optional external power supply. See attachment for additional information.

Categories: 

Split-Core Mini CT, 20 Amp

CopyBarcodeStatusProposal #NotesActions
4IDL-517AVAILABLE619.33V, 20 Amp
5IDL-506AVAILABLE522.33V, 20 Amp
Preview: 
Name: 
Split-Core AC CT, 20 Amp
Model: 
SCT-0400-020
Description: 

"Split-Core" Current Transformer (SCT) provides linear output voltage that is directly proportional to the input current. This current transformer is easily and safely installed over existing electrical power lines without disconnecting the lines or interrupting service. They are used for a variety of applications including building automation, performance verification, energy management and new technology assessment.Brands, Magnelab, Dent Instruments, Onset Computer Corp. See attachments for additional information.